Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Marine, OIL,GAS & Petrochemical Cables 

British Standard Shipwiring cables to BS 6883

Unarmoured flexible power cables

Unarmoured flexible power cables

The cables offer flexibility and a small overall diameter making routing and installation as easy as possible. Safety is ensured by the use of Low Smoke Halogen Free compounds.Unarmoured flexible power cables ideal for confined routing on ships and restricted areas.

Colour Codes

Cores can be identified using the following methods:
a) Colour coded.
1 Core Red or black
2 Core Red, black
3 Core Red, yellow, blue
4 Core Red, yellow, blue, black
5 Core and above Sequentially numbered

 b) Number coded - most popular for stock items.

Technical Information

Voltage rating 0.6/1kV
Conductors BS6360 class 2 or class 5
(Class 5 is generally manufactured to order)
Temperature rating +90°C maximum conductor temperature
Static temperature rating -30°C to +90°C
Bending radius (static) ≤ 10mm² 3 x cable O/D
    10mm² to 25mm² 4 x cable O/D
>  25mm² 4 x cable O/D
Flame retardant IEC60332 part 3A, BS4066 part 3A

Technical Data

Nominal area
of conductor
mm
Diameter over
outer sheath
min-max mm
 Single-core cables
 1   4.7 - 5.8 
 1.5   5.0 - 6.2 
 2.5   5.4 - 6.6 
 4   6.3 - 7.6 
 6   6.8 - 8.1 
 10   7.7 - 9.1 
 16   8.9 - 10.3 
 25   11.1 - 12.8 
 35   12.0 - 13.7 
 50   13.7 - 15.5 
 70   15.5 - 17.4 
 95   17.7 - 19.8 
 120   19.6 - 22.0 
 150   21.6 - 24.2 
 185   24.0 - 26.6 
 240   27.1 - 29.9 
 300   30.0 - 33.2 
 400   33.8 - 37.1 
 500   37.6 - 41.1 
 630   41.2 - 45.2 
 Two-core cables
 1   7.5 - 8.8 
 1.5   8.2 - 9.6 
 2.5   9.0 - 10.4 
 4   11.0 - 12.7 
 6   12.1 - 13.8 
 10   14.1 - 15.9 
 16   16.3 - 18.3 
 25   20.4 - 22.9 
 35   22.4 - 24.9 
 50   25.7 - 28.4 
 70   29.6 - 32.7 
 95   34.1 - 37.4 
 120   37.7 - 41.1 
 150   41.8 - 45.7 
 185   46.3 - 50.5 
 240   52.7 - 57.4 
 300   58.5 - 63.5 
Nominal area
of conductor
mm
Diameter over
outer sheath
min-max mm
 Three-core cables
 1   8.2 - 9.5 
 1.5   8.7 - 10.1 
 2.5   9.6 - 11.0 
 4   11.7 - 13.4 
 6   12.9 - 14.7 
 10   15.0 - 17.0 
 16   17.4 - 19.4 
 25   22.0 - 24.6 
 35   24.1 - 26.7 
 50   27.7 - 30.5 
 70   31.8 - 35.1 
 95   36.7 - 40.1 
 120   40.5 - 44.4 
 150   44.9 - 49.0 
 185   50.1 - 54.6 
 240   56.7 - 61.5 
 300   63.1 - 68.6 
 Four-core cables
 1   8.9 - 10.3 
 1.5   9.5 - 10.9 
 2.5   10.5 - 12.1 
 4   12.9 - 14.6 
 6   14.4 - 16.2 
 10   16.7 - 18.7 
 16   19.4 - 21.8 
 25   24.5 - 27.1 
 35   26.8 - 29.5 
 50   30.8 - 34.0 
 70   35.4 - 38.8 
 95   40.8 - 44.7 
 120   45.2 - 49.3 
 150   50.1 - 54.7 
 185   55.8 - 60.7 
 240   63.4 - 68.9 
 300   70.6 - 76.6 
  Five-core cables and above
 5x1.5   10.4 - 12.0 
 7x1.5   11.5 - 13.2 
 12x1.5   15.2 - 17.2 
 19x1.5   18.0 - 20.1 
 27x1.5   21.9 - 24.5 
 35x1.5   24.7 - 27.3 
 5x2.5   11.7 - 13.3 
 7x2.5   12.7 - 14.4 
 12x2.5   17.1 - 19.1 
 19x2.5   20.2 - 22.7